dc.description.abstractThe Management System for Operations and Combating Losses in the Low Voltage Electricity Distribution Network (SGRede-BT) is responsible for remotely monitoring, in real time, the electrical and physical parameters in each circuit of the low voltage electricity network through of remote measurement and data acquisition units (RUs), telesupervision software and database. During the firmware development process for the company's energy meters, developers are sometimes exposed to the risk of electric shock, given that they need to make connections at communication points that are close to live parts of the meter. The purpose of this project is to develop a prototype capable of generating signals that reproduce the behavior of a three-phase transformer in normal operation, and in events such as phase loss, overvoltage, undervoltage, and harmonics of up to 40th order, but generating these signals with negligible amplitude and powers, thus eliminating the risk of electric shock. For this, a system composed of a printed circuit board with a microcontroller, memory and digital/analog converters, and a control software capable of performing the necessary calculations to generate the waveforms that reproduce the aforementioned events will be used. Creating a reliable and secure environment for performing power meter firmware tests. As main results, it is possible to mention the successful implementation of a functional version of the hardware, firmware and software of the device, capable of generating signals that do not pose a risk of electric shock to the user and compatible with energy measurement devices.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade do Estado do Amazonaspt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectChoque Elétricopt_BR
dc.subjectConversor Digital/Analógicopt_BR
dc.subjectMicrocontroladorpt_BR
dc.subjectElectric Shockpt_BR
dc.subjectDigital/Analog Converterpt_BR
dc.subjectMicrocontrollerpt_BR
dc.titleDispositivo de simulação de transformador trifásico para validação de circuitos de medição de energia na etapa de pós condicionamentopt_BR
dc.title.alternativeThree-phase transformer simulation device for validating power measurement circuits in the post-conditioning stagept_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.date.accessioned2023-07-17T14:30:50Z-
dc.creator.ID9665397579772785pt_BR
dc.contributor.advisor1Oliveira, Jozias Parente de-
dc.contributor.advisor1ID1169202481169729pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1169202481169729pt_BR
dc.contributor.referee1Oliveira, Jozias Parente de-
dc.contributor.referee1ID1169202481169729pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1169202481169729pt_BR
dc.contributor.referee2Cardoso, Fábio de Sousa-
dc.contributor.referee2ID5612584109016079pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/5612584109016079pt_BR
dc.contributor.referee3Fernandes, Rubens de Andrade-
dc.contributor.referee3ID2548499974014028pt_BR
dc.contributor.referee3Latteshttp://lattes.cnpq.br/2548499974014028pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9665397579772785pt_BR
dc.description.resumoO Sistema de Gestão da Operação e Combate às Perdas em Rede de Distribuição de Energia Elétrica de Baixa Tensão (SGRede-BT) é responsável por monitorar remota e em tempo real os parâmetros elétricos e físicos em cada circuito da rede elétrica de baixa tensão por meio de unidades remotas de medição e aquisição de dados (URs), software de telesupervisão e banco de dados. Durante o processo de desenvolvimento do firmware dos medidores de energia da empresa, por vezes os desenvolvedores ficam expostos ao risco de choque elétrico, haja vista que precisam realizar ligações em pontos de comunicação que ficam próximos a partes vivas do medidor. Este projeto teve como objetivo desenvolver um protótipo capaz gerar sinais que reproduzam o comportamento de um transformador trifásico em funcionamento normal, e em eventos, tais como falta de fase, sobretensão, subtensão, e harmônicas de até 40ª ordem, mas gerando esses sinais com amplitude e potências irrisórias visando dessa forma eliminar o risco de choque elétrico. Para isso, foi utilizado um sistema composto por uma placa de circuito impresso com microcontrolador, memória e conversores digital/analógico, e um software de controle com capacidade de realizar os cálculos necessários para gerar as formas de onda que reproduzam os eventos supracitados, criando um ambiente confiável e seguro para realização dos testes de firmware do medidor de energia. Como principais resultados é possível mencionar o sucesso na implementação de uma versão funcional do hardware, firmware e software do dispositivo, esse capaz de gerar sinais que não apresentam risco de choque elétrico para o usuário e compatíveis com os dispositivos de medição de energia.pt_BR