dc.contributor.authorPimentel, Paulo André Magalhães-
dc.date.available2020-04-03-
dc.date.available2020-04-02T23:12:59Z-
dc.date.issued2019-12-16-
dc.identifier.urihttp://repositorioinstitucional.uea.edu.br//handle/riuea/2508-
dc.description.abstractBecoming a very important aspect on electrical installations nowadays, the power factor is filled with laws and fees to the customers who do not follow such rules. Not only aiming to preserve the generator unity, but also aiming to have a “cleaner” energy and to avoid facts like curt circuits and over tensions, it was created rules that limit some parameters related to the power factor, such as the excess of reactive energy used by the charge. Moreover, given to the fact that a great part of the actual electrical installations of buildings were built a very significant amount of time ago, the increase of reactive loads on its terminals, may result in the fees stablished before in case that there is not a proper correction of such problem. Therefore, picking as a place of study the Superior School of Technology in Amazonas, where the problem here mentioned occurred, this research will be elaborated aiming to dimension and study the viability of the implantation of a solution to such issue, using a bank of capacitors, in the Institution aiming to solve the problem.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade do Estado do Amazonaspt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectBanco capacitorpt_BR
dc.subjectFator de potênciapt_BR
dc.subjectEnergia reativa excedentept_BR
dc.subjectBank of capacitorspt_BR
dc.subjectPower factorpt_BR
dc.subjectExcess of reactive energypt_BR
dc.titleCorreção do fator de potência: estudo de viabilidade da Implantação de um banco capacitor na Universidade do Estado do Amazonas – Escola Superior De Tecnologiapt_BR
dc.title.alternativePower factor correction: feasibility study for the implementation of a capacitor bank at the State University of Amazonas - Escola Superior de Tecnologiapt_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.date.accessioned2020-04-02T23:12:59Z-
dc.creator.ID0413757594720042pt_BR
dc.contributor.advisor1Gomes, Raimundo Cláudio Souza-
dc.contributor.advisor1ID4244097441063312pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4244097441063312pt_BR
dc.contributor.referee1Torné, Israel Gondres-
dc.contributor.referee1ID1869557808967575pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1869557808967575pt_BR
dc.contributor.referee2Del Rio, Daniel Guzman Del Rio-
dc.contributor.referee2ID6465735602112961pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/6465735602112961pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0413757594720042pt_BR
dc.description.resumoTornando-se um aspecto de grande importância nas instalações elétricas, o fator de potência hoje em dia é regrado de leis e multas aos consumidores que não seguem tais regras. Não somente com o intuito da preservação da unidade geradora, mas também para a obtenção de uma energia mais “limpa” e para o fato de evitar curtos-circuitos ou sobretensões, criou-se regras que limitam alguns parâmetros que estão relacionados ao fator de potência, como, por exemplo, o excedente de energia reativa utilizada pela carga. Ademais, devido ao fato de muitas das instalações dos edifícios terem sido realizados há uma quantidade de tempo significativa, o aumento de cargas reativas nos terminais destas, pode acabar acarretando multas como as supracitadas caso não haja devida correção de tal problema. Assim, escolhendo como local de estudo a Escola Superior de Tecnologia, onde constatou-se tal problema, esta pesquisa será elaborada de forma a dimensionar e estudar a viabilidade da implantação de uma solução para esta questão, utilizando um banco capacitor, na Instituição visando à supressão do problema.pt_BR
dc.publisher.countryBrasilpt_BR
dc.subject.cnpqSistemas Eletrônicos de Medida e de Controlept_BR
dc.publisher.initialsUEApt_BR